Lenovo 6528 Manual do Utilizador Página 115

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 114
Removing the microprocessor and fan sink
To remove the microprocessor and fan sink, complete the following steps:
1. Read the safety information that begins on page vii and “Installation guidelines”
on page 29.
2. Turn off the server and all attached devices; then, disconnect all power cords
and external cables.
3. Turn the server on its side so that it is lying flat, with the cover facing up.
4. Unlock and remove the side cover (see “Removing the side cover” on page
32).
5. Remove the lower bezel (see “Removing the two-piece bezel” on page 34).
6. Remove the hard disk drives.
7. Press and hold the drive cage release tab; then, rotate the drive cage out of
the chassis until the retaining tab on top of the cage locks into place.
8. Disconnect any cables that impede access to the fan sink and microprocessor.
Attention: The fan-sink retention lever is spring-loaded when the fan sink is
in place. Releasing the lever too quickly or allowing it to spring upward can
damage the fan sink and surrounding components.
9. Remove the fan sink from the microprocessor:
a. Disconnect the fan-sink cable from the system board.
b. Release the fan-sink retention lever by pressing down on the end, moving
it to the side and slowly releasing it to the open (up) position.
Important: Be careful when you handle the microprocessor and fan sink.
If the microprocessor and fan sink will be reused, do not contaminate the
thermal material between them.
Chapter 6. Installing and replacing customer replaceable units 99
Vista de página 114
1 2 ... 110 111 112 113 114 115 116 117 118 119 120 ... 215 216

Comentários a estes Manuais

Sem comentários