Document Number: 318080-002 41
Electrical Specifications
5. Specification is for a minimum swing is specified into the test circuit described in Figure 2-11 and defined
between AGTL+ V
IL_MAX
to V
IH_MIN
. This assumes an edge rate of 2.0 V/ns to 3.0 V/ns.
6. RESET# can be asserted (active) asynchronously, but must be deasserted synchronously.
7. This should be measured after V
TT
and BCLK[1:0] become stable.
8. Maximum specification applies only while PWRGOOD is asserted.
.
Notes:
1. Unless otherwise noted, all specifications in this table apply to all processor frequencies.
2. Not 100% tested. Specified by design characterization.
3. All source synchronous AC timings are referenced to their associated strobe at nominal
GTLREF_DATA_MID, GTLREF_DATA_END, GTLREF_ADD_MID, and GTLREF_ADD_END. Source synchronous
data signals are referenced to the falling edge of their associated data strobe. Source synchronous address
signals are referenced to the rising and falling edge of their associated address strobe. All source
synchronous AGTL+ signal timings are referenced at nominal GTLREF_DATA_MID, GTLREF_DATA_END,
GTLREF_ADD_MID, and GTLREF_ADD_END at the processor core (pads).
4. Unless otherwise noted, these specifications apply to both data and address timings.
5. Valid delay timings for these signals are specified into the test circuit described in Figure 2-11 and with
GTLREF_DATA_MID, GTLREF_DATA_END, GTLREF_ADD_MID, and GTLREF_ADD_END at 0.67 * V
TT
.
6. Specification is for a minimum swing into the test circuit described in Figure 2-11 and defined between
AGTL+ V
IL_MAX
to V
IH_MIN
. This assumes an edge rate of 3.0 V/ns to 5.5 V/ns.
7. All source synchronous signals must meet the specified setup time to BCLK as well as the setup time to
each respective strobe.
8. This specification represents the minimum time the data or address will be valid before its strobe. Refer to
the appropriate platform design guidelines for more information on the definitions and use of these
specifications.
9. This specification represents the minimum time the data or address will be valid after its strobe. Refer to
the appropriate platform design guidelines for more information on the definitions and use of these
specifications.
10. The rising edge of ADSTB# must come approximately 1/2 BCLK period after the falling edge of ADSTB#.
11. For this timing parameter, n = 1, 2, and 3 for the second, third, and last data strobes respectively.
12. The address strobe setup time is measured with respect to T2. Calculation of the setup time is as follows.:
a. If T27 > BCLK period, then the setup time calculated is positive. The value calculated indicates
setup time before T1.
b. If T27 < BCLK period, then the setup time calculated is negative. The value calculated indicates
setup time after T1. Refer to Figure 2-17.
13. This specification applies only to DSTBN[3:0]# and is measured to the second falling edge of the strobe.
14. This specification reflects a typical value, not a minimum or maximum.
15. For this timing parameter, n = 0 to 1.
Table 2-21. FSB Source Synchronous AC Specifications
T# Parameter Min Max Unit Figure Notes
1, 2, 3, 4
T20: Source Sync. Output Valid Delay
(first data/address only)
0.00 1.10 ns 2-17,
2-18
5
T21: T
VBD
Source Sync. Data Output
Valid Before Data Strobe
0.270 ns 2-18 5,8
T22: T
VAD
Source Sync. Data Output
Valid After Data Strobe
0.270 ns 2-18 5,9
T23: T
VBA
Source Sync. Address Output
Valid Before Address Strobe
0.660 ns 2-17 5,8
T24: T
VAA
Source Sync. Address Output
Valid After Address Strobe
0.660 ns 2-17 5,9
T25: T
SUSS
Data Input Setup Time 0.190 ns 2-17 2-18 6
T25: T
SUSS
Address Input Setup Time 0.300 ns 2-17,
2-18
6
T26: T
HSS
Data Input Hold Time 0.190 ns 2-17,
2-18
6
T26: T
HSS
Address Input Hold Time 0.300 ns 2-17,
2-18
6
T27: Source Synchronous Address
Strobe Setup Time to BCLK[1:0]
3.5 -
(1.875 * n)
ns 2-17 12, 14, 15
T28: Source Synchronous Data Strobe
Setup Time to BCLK[1:0]
4.15 -
(0.9375 * n)
ns 2-18 11,14
T30: Data Strobe ‘n’ (DSTBN#) Output
Valid Delay
3.28 4.38 ns 2-18 13
T31: Address Strobe Output Valid Delay 2.81 3.91 ns 2-17