Lenovo THINKSERVER RS210 Manual do Utilizador Página 169

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 244
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 168
4. Remove the cover (see “Removing and installing the cover” on page 119).
5. Remove the riser-card assembly (see “Removing the riser-card assembly” on page 157).
6. Touch the static-protective package that contains the new ServeRAID-BR10il SAS/SATA controller to
any unpainted surface on the outside of the server; then, grasp the controller by the top edge or
upper corners of the controller and remove it from the package.
7. Align the ServeRAID controller 1 so that the keys align correctly with the connector 2 on the
system board.
8. Insert the ServeRAID controller into the connector on the system board until it is firmly seated. The
retention bracket secures the ServeRAID controller in place when the controller is firmly seated into
the connector on the system board.
Attention: Incomplete insertion might cause damage to the server or the controller.
9. Route the signal cables from the drive backplane through the fan cage hole (between fans 1 and 2) as
shown in the following illustration.
Chapter 6. Replacing FRUs 161
Vista de página 168
1 2 ... 164 165 166 167 168 169 170 171 172 173 174 ... 243 244

Comentários a estes Manuais

Sem comentários